期刊论文详细信息
Journal of Cardiovascular Magnetic Resonance
Quantitative myocardial perfusion in mice based on the signal intensity of flow sensitized CMR
Research
Sumeda Abeykoon1  Michelle Sargent2  Janaka P Wansapura3 
[1] Department of Physics, University of Cincinnati, Cincinnati, OH, USA;Imaging Research Center, Department of Radiology, Cincinnati Children's Hospital, 3333 Burnet Ave, MLC 5033, 45229, Cincinnati, OH, USA;Howard Hughes Medical Institute, Molecular Cardiovascular Biology, Cincinnati Children Hospital, Cincinnati, OH, USA;Imaging Research Center, Department of Radiology, Cincinnati Children's Hospital, 3333 Burnet Ave, MLC 5033, 45229, Cincinnati, OH, USA;
关键词: Myocardial perfusion;    T1;    Mice;    Arterial spin labeling;   
DOI  :  10.1186/1532-429X-14-73
 received in 2012-05-16, accepted in 2012-10-11,  发布年份 2012
来源: Springer
PDF
【 摘 要 】

BackgroundIn the conventional approach to arterial spin labeling in the rodent heart, the relative difference in the apparent T1 relaxation times corresponding to selective and non-selective inversion is related to perfusion via a two compartment model of tissue. But accurate determination of T1 in small animal hearts is difficult and prone to errors due to long scan times and high heart rates. In this study we introduce the theoretical frame work for an alternative method (SI-method) based purely on the signal intensity of slice-select and non-select inversion recovery images at a single inversion time at short repetition time.MethodsA modified Bloch equation was solved to derive perfusion as a function of signal intensity of flow sensitized segmented gradient echo acquisitions. A two compartment fast exchanging model of tissue was assumed. To test the new technique first it was implemented on a flow phantom and then it was compared with the conventional T1 method in an in vivo study of healthy C57BL/6 mice (n=12). Finally the SI-method was used in comparison to a Late Gadolinium Enhanced (LGE) method to qualitatively and quantitatively assess perfusion deficits in an ischemia-reperfusion mouse model (n=4).ResultsThe myocardial perfusion of healthy mice obtained by the SI-method, 5.6 ± 0.5 ml/g/min, (mean ± standard deviation) was similar (p=0.38) to that obtained by the conventional method, 5.6 ± 0.3 ml/g/min. The variance in perfusion within the left ventricle was less for the SI-method than that for the conventional method (p<0.0001). The mean percentage standard deviation among repeated measures was 3.6%. The LGE regions of the ischemia reperfusion model were matched with regions of hypo-perfusion in the perfusion map. The average perfusion in the hypo perfused region among all four IR mice was 1.2 ± 0.9 ml/g/min and that of the remote region was 4.4 ± 1.2 ml/g/min.ConclusionsThe proposed signal intensity based ASL method with a segmented acquisition scheme allows accurate high resolution perfusion mapping in small animals. It’s short scan time, high reproducibility and ease of post process makes it a robust alternative to the conventional ASL technique that relies on T1 measurements.

【 授权许可】

Unknown   
© Abeykoon et al.; licensee BioMed Central Ltd. 2012. This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.