QUANTIFICATION OF MERCURY IN FLUE GAS EMISSION USING BORON-DOPED DIAMOND ELECTROCHEMISTRY | |
Manivannan, A. ; Seehra, M.S. | |
West Virginia University (United States) | |
关键词: Mercury; Detection; 54 Environmental Sciences; Electrochemistry; Air Pollution Monitoring; | |
DOI : 10.2172/821152 RP-ID : NONE RP-ID : FG26-01NT41291 RP-ID : 821152 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
In this project, we have attempted to develop a new technique utilizing Boron-doped diamond (BDD) films to electrochemically detect mercury dissolved in solution via the initial deposition of metallic mercury, followed by anodic linear sweep voltammetry in the range from 10-10{sup -10} M to 10{sup -5} M. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques were employed. The extremely low background current for BDD electrodes compared to glassy carbon (GC) provides a strong advantage in trace metal detection. CV peak currents showed good linearity in the micromolar range. A detection level of 6.8 x 10{sup -10} M was achieved with DPV in 0.1 M KNO{sub 3} (pH = 1) for a deposition time of 20 minutes. Reproducible stripping peaks were obtained, even for the low concentration range. A comparison with GC shows that BDD is superior. Linear behavior was also obtained in the mercury concentration range from 10{sup -10} M to 10{sup -9} M.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
821152.pdf | 244KB | download |