科技报告详细信息
QUANTIFICATION OF MERCURY IN FLUE GAS EMISSION USING BORON-DOPED DIAMOND ELECTROCHEMISTRY
Manivannan, A. ; Seehra, M.S.
West Virginia University (United States)
关键词: Mercury;    Detection;    54 Environmental Sciences;    Electrochemistry;    Air Pollution Monitoring;   
DOI  :  10.2172/821152
RP-ID  :  NONE
RP-ID  :  FG26-01NT41291
RP-ID  :  821152
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

In this project, we have attempted to develop a new technique utilizing Boron-doped diamond (BDD) films to electrochemically detect mercury dissolved in solution via the initial deposition of metallic mercury, followed by anodic linear sweep voltammetry in the range from 10-10{sup -10} M to 10{sup -5} M. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques were employed. The extremely low background current for BDD electrodes compared to glassy carbon (GC) provides a strong advantage in trace metal detection. CV peak currents showed good linearity in the micromolar range. A detection level of 6.8 x 10{sup -10} M was achieved with DPV in 0.1 M KNO{sub 3} (pH = 1) for a deposition time of 20 minutes. Reproducible stripping peaks were obtained, even for the low concentration range. A comparison with GC shows that BDD is superior. Linear behavior was also obtained in the mercury concentration range from 10{sup -10} M to 10{sup -9} M.

【 预 览 】
附件列表
Files Size Format View
821152.pdf 244KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:19次