科技报告详细信息
Quantification of Mercury in Flue Gas Emission using Boron-doped Diamond Electrochemistry.
Manivannan, A. ; Seehra, M. S.
Technical Information Center Oak Ridge Tennessee
关键词: Mercury;    Flue gases;    Gas emissions;    Electrochemistry;    Air pollution monitoring;   
RP-ID  :  DE2004821152
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】
In this project, we have attempted to develop a new technique utilizing Boron-doped diamond (BDD) films to electrochemically detect mercury dissolved in solution via the initial deposition of metallic mercury, followed by anodic linear sweep voltammetry in the range from 10-10(sup -10) M to 10(sup -5) M. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques were employed. The extremely low background current for BDD electrodes compared to glassy carbon (GC) provides a strong advantage in trace metal detection. CV peak currents showed good linearity in the micromolar range. A detection level of 6.8 x 10(sup -10) M was achieved with DPV in 0.1 M KNO(sub 3) (pH= 1) for a deposition time of 20 minutes. Reproducible stripping peaks were obtained, even for the low concentration range. A comparison with GC shows that BDD is superior. Linear behavior was also obtained in the mercury concentration range from 10(sup -10) M to 10(sup -9) M.
【 预 览 】
附件列表
Files Size Format View
DE2004821152.pdf 197KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:10次