Pilot study using 3D–longitudinal strain computation in a multi-parametric approach for best selecting responders to cardiac resynchronization therapy
Research
J. Claude Daubert1  Elena Galli1  Christophe Leclercq1  Philippe Mabo1  Maxime Fournet1  Raphael Martins1  Erwan Donal2  Alfredo Hernandez3  Anne Bernard4  Sylvestre Marechaux5 
[1] Cardiologie et CIC-IT 1414, Centre Hospitalier Universitaire de Rennes, F-35000, Rennes, France;LTSI, Université Rennes 1, INSERM, F-35000, Rennes, France;Cardiologie et CIC-IT 1414, Centre Hospitalier Universitaire de Rennes, F-35000, Rennes, France;LTSI, Université Rennes 1, INSERM, F-35000, Rennes, France;Service de Cardiologie, Hôpital Pontchaillou, CHU Rennes, F-35033, Rennes, France;LTSI, Université Rennes 1, INSERM, F-35000, Rennes, France;LTSI, Université Rennes 1, INSERM, F-35000, Rennes, France;Service de Cardiologie, CHU Tours, F-37000, Tours, France;Service de Cardiologie, Saint Philibert Catholic University Hospital, Lille, France;
关键词: Three-dimensional echocardiography;    Heart failure;    Cardiac resynchronization therapy;    Dyssynchrony;   
DOI  :  10.1186/s12947-017-0107-6
 received in 2017-05-04, accepted in 2017-06-05,  发布年份 2017
来源: Springer
PDF
【 摘 要 】

BackgroundAlmost all attempts to improve patient selection for cardiac resynchronization therapy (CRT) using echo-derived indices have failed so far. We sought to assess: the performance of homemade software for the automatic quantification of integral 3D regional longitudinal strain curves exploring left ventricular (LV) mechanics and the potential value of this tool to predict CRT response.MethodsForty-eight heart failure patients in sinus rhythm, referred for CRT-implantation (mean age: 65 years; LV-ejection fraction: 26%; QRS-duration: 160 milliseconds) were prospectively explored. Thirty-four patients (71%) had positive responses, defined as an LV end-systolic volume decrease ≥15% at 6-months. 3D–longitudinal strain curves were exported for analysis using custom-made algorithms. The integrals of the longitudinal strain signals (IL,peak) were automatically measured and calculated for all 17 LV-segments.ResultsThe standard deviation of longitudinal strain peak (SDIL,peak) for all 17 LV-segments was greater in CRT responders than non-responders (1.18% s−1 [0.96; 1.35] versus 0.83% s−1 [0.55; 0.99], p = 0.007). The optimal cut-off value of SDIL,peak to predict response was 1.037%.s−1. In the 18-patients without septal flash, SDIL,peak was significantly higher in the CRT-responders.ConclusionsThis new automatic software for analyzing 3D longitudinal strain curves is avoiding previous limitations of imaging techniques for assessing dyssynchrony and then its value will have to be tested in a large group of patients.

【 授权许可】

CC BY   
© The Author(s). 2017

【 预 览 】
附件列表
Files Size Format View
RO202311108835213ZK.pdf 722KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  文献评价指标  
  下载次数:1次 浏览次数:1次