期刊论文详细信息
International Journal of Implant Dentistry
A novel approach to determining augmented bone volume in intraoral bone block augmentation using an intraoral scanner: an in vitro study
Technical Advances Article
Kalchthaler Lukas1  Weichel Frederic1  Mertens Christian1  Ristow Oliver1  Freudlsperger Christian1  Hoffmann Jürgen1  Engel Michael1  Kühle Reinald1  Büsch Christopher2 
[1] Department of Oral‐ and Cranio‐Maxillofacial Surgery, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany;Institute of Medical Biometry, University Heidelberg, Im Neuenheimer Feld 130.3, 69120, Heidelberg, Germany;
关键词: Bone augmentation;    Bone regeneration;    Autogenous bone;    Bone blocks, intraoral bone graft;    Automated volume measurement;   
DOI  :  10.1186/s40729-023-00492-0
 received in 2023-03-01, accepted in 2023-08-29,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

IntroductionBone augmentation procedures are established tools for reshaping the alveolar ridge and increasing bone volume. Different approaches are being used to measure postoperative bone volume gain. This study aimed to develop an objective and automated volume measurement tool equally as precise as manual slice-by-slice annotation.Materials and methodsTo evaluate the proposed workflow, we performed an in vitro study with 20 pig mandibles that were grafted using three different grafting techniques—autogenous full block, split block bone and shell augmentation. The pig jaws were scanned pre- and postoperatively using an intraoral scanner. The resulting surface files (baseline, full block, split block, shell) were processed using the new volume-measuring workflow as well as using manual slice-by-slice annotation at baseline (t0) and at 6 months (t1) using the same population. Two TOSTs (Test of One-Sided Significance) and NHSTs (Null Hypothesis Significance Test) were used to compare the two workflows. The intra-rater reliability between t0 and t1 was determined using intraclass correlation coefficients.ResultsThe mean difference for the full block augmentation technique was − 0.015 cm3 (p < 0.001); for the split block technique, it was − 0.034 cm3p = 0.01, and for the shell technique, it was − 0.042 cm3. All results were statistically not different from zero and statistically equivalent to zero. The results also showed an excellent absolute intra-rater agreement.ConclusionsThe semiautomatic volume measurement established in this article achieves comparable results to manual slice-by-slice measuring in determining volumes on STL files generated by intraoral scanners and shows an excellent intra-rater reliability.Graphical Abstract

【 授权许可】

CC BY   
© Deutsche Gesellschaft für Implantologie im Zahn‐, Mund‐ und Kieferbereich e.V., Japanese Society of Oral Implantology 2023

【 预 览 】
附件列表
Files Size Format View
RO202310114495431ZK.pdf 2701KB PDF download
Fig. 1 472KB Image download
Fig. 2 357KB Image download
13690_2023_1170_Article_IEq112.gif 1KB Image download
Fig. 1 1571KB Image download
Fig. 2 2464KB Image download
MediaObjects/41408_2023_905_MOESM1_ESM.docx 75KB Other download
12888_2023_5172_Article_IEq32.gif 1KB Image download
MediaObjects/13690_2023_1188_MOESM5_ESM.pdf 178KB PDF download
Fig. 2 700KB Image download
【 图 表 】

Fig. 2

12888_2023_5172_Article_IEq32.gif

Fig. 2

Fig. 1

13690_2023_1170_Article_IEq112.gif

Fig. 2

Fig. 1

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  文献评价指标  
  下载次数:2次 浏览次数:0次