会议论文详细信息
2017 4th International Conference on Advanced Materials, Mechanics and Structural Engineering
Evaluation on Bending Properties of Biomaterial GUM Metal Meshed Plates for Bone Graft Applications
材料科学;机械制造
Suzuki, Hiromichi^1 ; He, Jianmei^1
Dept. of Mechanical Engineering, Kogakuin Univ., 1-24-2 Nishi-shinjuku, Shinjuku-ku, Tokyo
163-8677, Japan^1
关键词: 3-point bending;    3D CAD Modeling;    Analytical approach;    Analytical results;    Artificial bones;    Autogenous bone;    Bending elastic modulus;    Bending properties;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/269/1/012078/pdf
DOI  :  10.1088/1757-899X/269/1/012078
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

There are three bone graft methods for bone defects caused by diseases such as cancer and accident injuries: Autogenous bone grafts, Allografts and Artificial bone grafts. In this study, meshed GUM Metal plates with lower elasticity, high strength and high biocompatibility are introduced to solve the over stiffness & weight problems of ready-used metal implants. Basic mesh shapes are designed and applied to GUM Metal plates using 3D CAD modeling tools. Bending properties of prototype meshed GUM Metal plates are evaluated experimentally and analytically. Meshed plate specimens with 180°, 120° and 60° axis-symmetrical types were fabricated for 3-point bending tests. The pseudo bending elastic moduli of meshed plate specimens obtained from 3-point bending test are ranged from 4.22 GPa to 16.07 GPa, within the elasticity range of natural cortical bones from 2.0 GPa to 30.0 GPa. Analytical approach method is validated by comparison with experimental and analytical results for evaluation on bending property of meshed plates.

【 预 览 】
附件列表
Files Size Format View
Evaluation on Bending Properties of Biomaterial GUM Metal Meshed Plates for Bone Graft Applications 489KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:33次