2nd International Conference on Computational Fluid Dynamics in Research and Industry | |
The study of flow and heat transfer characteristics of impinging jet array mounting air-induced duct | |
力学;计算机科学;工业技术 | |
Yeranee, K.^1 ; Wae-Hayee, M.^1 ; Piya, I.^2 ; Rao, Y.^3 ; Nuntadusit, C.^1 | |
Department of Mechanical Engineering, Faculty of Engineering, Prince of Songkla University, Songkhla, Thailand^1 | |
Department of Mechanical Engineering, Princess of Naradhiwas University, Naradhiwas, Thailand^2 | |
School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China^3 | |
关键词: Flow and heat transfer; High heat transfers; Impingement regions; Impingement surfaces; In-line configuration; Jet-to-plate distances; Thin foil technique; Turbulence intensity; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/243/1/012001/pdf DOI : 10.1088/1757-899X/243/1/012001 |
|
来源: IOP | |
【 摘 要 】
Impinging jet is widely employed in thermal industrial applications due to having high heat transfer coefficient in impingement region. One method to increase heat transfer on an impingement surface is to increase turbulence intensity in jet flow. The mounting of an air-induced duct at nozzle outlet is a passive method to increase entrainment air resulting on increasing turbulence intensity. The aim of this research is to study flow and heat transfer characteristics of array of impinging jets mounting air-induced ducts. The investigation model was jets discharging from pipe nozzle having an inner diameter of d=17.2 mm and a length of 200 mm. Nozzle arrangement were inline configuration having 5 rows x 5 columns. A jet-to-jet distance (S) was S=6d, 8d and a jet-to-plate distance (H) was H=6d. The inner diameter (D) and the length (L) of the air-induced ducts were D=4d and L=4d, respectively. The Reynolds number was fixed at Re=20,000. In addition, the impinging jets without mounting the air-induced ducts were also investigated for benchmarking with the case of mounting the air-induced ducts. In the study, a thin foil technique was used to measure heat transfer on the impingement surface, and a computational fluid dynamic (CFD) using ANSYS, Fluent (V.15.0) was also adopted. The results showed that the effect of mounting air-induced duct can enhance entrainment air into the jet flow resulting on increasing of heat transfer of impinging jets on target surface, and the effects of mounting air-induced duct on increasing heat transfer in case of larger jet-to-jet distance (S/d=8) was more effective than that of smaller jet-to-jet distance (S/d=6).
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
The study of flow and heat transfer characteristics of impinging jet array mounting air-induced duct | 1298KB | download |