会议论文详细信息
5th International Conference on Science & Engineering in Mathematics, Chemistry and Physics 2017
Experimental Demonstration of the Dependence of Temperature Decrease on the Hydraulic Radius of Regenerator in a Traveling-Wave Thermoacoustic Refrigerator
数学;化学;物理学
Setiawan, Ikhsan^1 ; Fadly, Muhammad N.M.^1 ; Utomo, Agung B.S.^1
Departement of Physics, Faculty of Mathematics and Natural Sciences, Universitas Gadjah Mada, Sekip Utara BLS 21, Yogyakarta
55281, Indonesia^1
关键词: Environmentally benign;    Experimental demonstrations;    Hydraulic radius;    Operating frequency;    Stainless steel wire meshes;    Temperature decrease;    Thermal penetration depths;    Thermoacoustic refrigerators;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/820/1/012012/pdf
DOI  :  10.1088/1742-6596/820/1/012012
来源: IOP
PDF
【 摘 要 】

Thermoacoustic refrigerators are cooling devices that employ sound wave in heat removal process. They mostly use air or other inert gas as working fluid and hence they are environmentally benign. The cooling process takes place in a porous medium (regenerator or stack). This paper presents an experiment on a loudspeaker-driven traveling-wave thermoacoustic refrigerator to demonstrate the dependence of temperature decrease on the hydraulic radius (rh) of regenerator. The refrigerator has a looped tube and a resonator tube, with the length of 260 cm and 150 cm, respectively. Six different regenerators are used, each of which is made of a tight stack of stainless-steel wire-mesh screens with different mesh sizes, providing rhfrom 0.07 mm until 0.28 mm. The regenerator length is 60 mm. Atmospheric air is used as the working gas, driven at operating frequency of 30 Hz, giving thermal penetration depth (δκ) of 0.49 mm. The experimental results show that there is an optimum rhwhich gives the largest temperature decrease at the cooling point. It is found, in this case, that the optimum rhis 0.10 mm (that is, rh/δκ= 0.20) and the corresponding temperature decrease is 18.7°C (i.e. from 28.0 °C down to 9.3 °C).

【 预 览 】
附件列表
Files Size Format View
Experimental Demonstration of the Dependence of Temperature Decrease on the Hydraulic Radius of Regenerator in a Traveling-Wave Thermoacoustic Refrigerator 2310KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:23次