科技报告详细信息
Results of Vapor Space Monitoring Flammable Gas Watch List Tanks.
McCain, D. J.
Technical Information Center Oak Ridge Tennessee
关键词: Hanford Reservation;    Tanks;    Monitoring;    Flammable gases;    Headspace gases;   
RP-ID  :  DE2003804812
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

This report documents the measurement of headspace gas concentrations and monitoring results from the Hanford tanks that have continuous flammable gas monitoring. The systems used to monitor the tanks are Standard Hydrogen Monitoring Systems. Further characterization of the tank off-gases was done with Gas Characterization systems and vapor grab samples. The background concentrations of all tanks are below the action level of 6250 ppm. Other information which can be derived from the measurements (such as generation rate, released rate, and ventilation rate) is also discussed.

【 预 览 】
附件列表
Files Size Format View
DE2003804812.pdf 3839KB PDF download
  文献评价指标  