科技报告详细信息
| Schottky measurements during rhic 2000. | |
| Cameron, ; Cupolo, ; Degen, ; Hammons, ; Kesselman, | |
| Technical Information Center Oak Ridge Tennessee | |
| 关键词: Schottky effect; Brookhaven RHIC; Diagnostic techniques; Chromaticity; Resonance; | |
| RP-ID : DE2001784219 | |
| 学科分类:工程和技术(综合) | |
| 美国|英语 | |
| 来源: National Technical Reports Library | |
PDF
|
|
【 摘 要 】
The 2GHz Schottky system was a powerful diagnostic during RHIC 2000 commissioning. A continuous monitor without beam excitation, it provided betatron tune, chromaticity, momentum spread relative emittance, and synchrotron tune. It was particularly useful during transition studies. In addition, a BPM was resonated at 230MHz for Schottky measurements.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| DE2001784219.pdf | 298KB |
PDF