科技报告详细信息
Schottky measurements during rhic 2000. | |
Cameron, ; Cupolo, ; Degen, ; Hammons, ; Kesselman, | |
Technical Information Center Oak Ridge Tennessee | |
关键词: Schottky effect; Brookhaven RHIC; Diagnostic techniques; Chromaticity; Resonance; | |
RP-ID : DE2001784219 | |
学科分类:工程和技术(综合) | |
美国|英语 | |
来源: National Technical Reports Library | |
【 摘 要 】
The 2GHz Schottky system was a powerful diagnostic during RHIC 2000 commissioning. A continuous monitor without beam excitation, it provided betatron tune, chromaticity, momentum spread relative emittance, and synchrotron tune. It was particularly useful during transition studies. In addition, a BPM was resonated at 230MHz for Schottky measurements.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
DE2001784219.pdf | 298KB | download |