科技报告详细信息
MEASURED AND CALCULATED HEATING AND DOSE RATES FOR THE HFIR HB4 BEAM TUBE AND COLD SOURCE
Slater, Charles O ; Primm, Trent ; Pinkston, Daniel ; Cook, David Howard ; Selby, Douglas L ; Ferguson, Phillip D ; Bucholz, James A ; Popov, Emilian L
Oak Ridge National Laboratory
关键词: Heating;    Teflon;    Neutrons;    Hfir Reactor;    Ornl;   
DOI  :  10.2172/951614
RP-ID  :  ORNL/TM-2009/012
RP-ID  :  DE-AC05-00OR22725
RP-ID  :  951614
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The High Flux Isotope Reactor at the Oak Ridge National Laboratory was upgraded to install a cold source in horizontal beam tube number 4. Calculations were performed and measurements were made to determine heating within the cold source and dose rates within and outside a shield tunnel surrounding the beam tube. This report briefly describes the calculations and presents comparisons of the measured and calculated results. Some calculated dose rates are in fair to good agreement with the measured results while others, particularly those at the shield interfaces, differ greatly from the measured results. Calculated neutron exposure to the Teflon seals in the hydrogen transfer line is about one fourth of the measured value, underpredicting the lifetime by a factor of four. The calculated cold source heating is in good agreement with the measured heating.

【 预 览 】
附件列表
Files Size Format View
951614.pdf 1073KB PDF download
  文献评价指标  