科技报告详细信息
Aquifer Testing Recommendations for Well 299-W15-225: Supporting Phase I of the 200-ZP-1 Groundwater Operable Unit Remedial Design
Spane, Frank A. ; Newcomer, Darrell R.
Pacific Northwest National Laboratory (U.S.)
关键词: Technetium 99;    Iodine 129;    Testing;    Recommendations;    Tritium;   
DOI  :  10.2172/949909
RP-ID  :  PNNL-18279
RP-ID  :  AC05-76RL01830
RP-ID  :  949909
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

Aquifer characterization needs are currently being assessed to optimize pump-and-treat remedial strategies within the 200-ZP-1 Operable Unit (OU), specifically for the immediate area of the 241-TX-TY Tank Farm. Currently, 14 extraction wells are actively used in the Interim Record of Decision ZP-1 pump-and-treat system to remediate the existing groundwater contamination within this general area. Four of these wells (299-W15-40, 299-W15-43, 299-W15-44, and 299-W15-765) are targeted to remediate contamination within the immediate 241-TX-TY Tank Farm area. The major contaminant of concern (COC) for the 200-ZP-1 OU is carbon tetrachloride. Other COC’s include total chromium (trivalent [III] and hexavalent [VI], nitrate, trichloroethlyene, iodine-129, technetium-99, and tritium.

【 预 览 】
附件列表
Files Size Format View
949909.pdf 437KB PDF download