CALCULATION OF DEMONSTRATION BULK VITRIFICATION SYSTEM MELTER INLEAKAGE AND OFF-GAS GENERATION RATE | |
TH, MAY | |
Hanford Site (Wash.) | |
关键词: Testing; Waste Forms; Rivers; Wastes; Storage Facilities; | |
DOI : 10.2172/927412 RP-ID : RPP-CALC-35435 Rev 0 RP-ID : DE-AC27-99RL14047 RP-ID : 927412 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The River Protection Project (RPP) mission is to safely store, retrieve, treat, immobilize, and dispose of the Hanford Site tank waste. The Demonstration Bulk Vitrification System (DBVS) is a research and development project whose objective is to demonstrate the suitability of Bulk Vitrification treatment technology waste form for disposing of low-activity waste from the Tank Farms. The objective of this calculation is to determine the DBVS melter inleakage and off-gas generation rate based on full scale testing data from 38D. This calculation estimates the DBVS melter in leakage and gas generation rate based on test data. Inleakage is estimated before the melt was initiated, at one point during the melt, and at the end of the melt. Maximum gas generation rate is also estimated.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
927412.pdf | 613KB | download |