This specification establishes the performance requirements and provides references to the requisite codes and standards to be applied during design of the Double-Shell Tank (DST) Transfer Valving Subsystem that supports the first phase of Waste Feed Delivery. This specification establishes the performance requirements and provides references to the requisite codes and standards to be applied during design of the Double-Shell Tank (DST) Transfer Valving Subsystem that supports the first phase of Waste Feed Delivery (WFD). The DST Transfer Valving Subsystem routes waste and other media (e.g., diluent, flush water, filtered raw water) among DSTs and from the low-activity waste (LAW) and high-level waste (HLW) feed staging tanks to the River Protection Project (RPP) Privatization Contractor facility, where it will be processed into an immobilized waste form. This specification is intended to be the basis for new projects/installations (W-521, etc.). This specification is not intended to retroactively affect previously established project design criteria without specific direction by the program.