A least squares method for CVT calibration in a RLC capacitor discharge circuit. | |
Yao, Stephen E. ; Dickey, Fred McCartney ; Pecak, Sara North | |
Sandia National Laboratories | |
关键词: Calibration; Monitoring; Capacitors; 42 Engineering; Reliability; | |
DOI : 10.2172/918301 RP-ID : SAND2003-3932 RP-ID : AC04-94AL85000 RP-ID : 918301 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
In many applications, the ability to monitor the output of a capacitive discharge circuit is imperative to ensuring the reliability and accuracy of the unit. This monitoring is commonly accomplished with the use of a Current Viewing Transformer (CVT). In order to calibrate the CVT, the circuit is assembled with a Current Viewing Transformer (CVR) in addition to the CVT and the peak outputs compared. However, difficulties encountered with the use of CVRs make it desirable to eliminate the use of the CVR from the calibration process. This report describes a method for determining the calibration factor between the current throughput and the CVT voltage output in a capacitive discharge unit from the CVT ringdown data and values of initial voltage and capacitance of the circuit. Previous linear RLC fitting work for determining R, L, and C is adapted to return values of R, L, and the calibration factor, k. Separate solutions for underdamped and overdamped cases are presented and implemented on real circuit data using MathCad software with positive results. This technique may also offer a unique approach to self calibration of current measuring devices.