| DETERMINATION OF THE AGR-1 CAPSULE TO FPMS SPECTROMETER TRANSPORT VOLUMES FROM LEADOUT FLOW TEST DATA | |
| Hartwell, J. K. ; Walter, J. B. ; Scates, D. M. ; Drigert, M. W. | |
| Idaho National Laboratory | |
| 关键词: Spectrometers; Flow Rate; Monitoring; Irradiation; Radioisotopes; | |
| DOI : 10.2172/911969 RP-ID : INL/EXT-07-12494 RP-ID : DE-AC07-99ID-13727 RP-ID : 911969 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
The AGR-1 experiment is a fueled multiple-capsule irradiation experiment being conducted in the Advanced Test Reactor (ATR) in support of the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. A flow experiment conducted during the AGR-1 irradiation provided data that included the effect of flow rate changes on the decay of a short-lived radionuclide (23Ne). This data has been analyzed to determine the capsule-specific downstream transport volume through which the capsule effluents must pass before arrival at the fission product monitoring system spectrometers. These resultant transport volumes when coupled with capsule outlet flow rates determine the transport times from capsule-to-detector. In this work an analysis protocol is developed and applied in order to determine capsule-specific transport volumes to precisions of better than +/- 7%.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 911969.pdf | 225KB |
PDF