科技报告详细信息
Summary of ACSL Simulations of the MSRE Auxiliary Charcoal Bed Vacuum System
Damiano, B
Oak Ridge National Laboratory
关键词: Charcoal;    Modifications;    Testing;    Mockup;    Cyclone Separators;   
DOI  :  10.2172/885543
RP-ID  :  ORNL/TM-1999/333
RP-ID  :  DE-AC05-00OR22725
RP-ID  :  885543
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】
The simulation of the Auxiliary Charcoal Bed (ACB) Vacuum System was performed to evaluate the original vacuum system design, detect and identify design deficiencies, investigate the effects of proposed corrections on system performance, and generally aid in refining the system design before construction and mockup testing. The simulation was performed by using the Advanced Continuous Simulation Language (ACSL). The vacuum system design goals are to provide approximately 20 SCFM of both booster gas and purge gas through the system and maintain a flow of approximately 40 SCFM with a velocity of 50 to 75 f/sec at the entrance to the cyclone separator. The model results showed that the original system design was incapable of meeting the system performance goals. Further simulations showed that the following modifications to the original vacuum system design were required to make the system performance acceptable; (1) Remove valve PCV4. (2) Modify the flow controllers FTC3 and FTC4 from the original flow range of 0-17.6 SCFM (0-500 SLM) to 0-35.3 SCFM (0-1000 SLM). (3) Replace the bellows sealed valves SV-1, SV-3A, SV-3B, SV-4A, and SV-4B with less restrictive ball valves. The simulation results saved considerable time and effort by identifying flaws in the original system design. Early identification of these flaws and the use of the simulation model to investigate possible solutions allowed corrective modifications to be made before construction of the mock up test facility.
【 预 览 】
附件列表
Files Size Format View
885543.pdf 632KB PDF download
  文献评价指标  
  下载次数:4次 浏览次数:23次