科技报告详细信息
EVALUATION OF VADOSE ZONE TREATMENT TECHNOLOGIES TO IMMOBILIZE TECHNETIUM-99
PETERSEN, S.W.
Hanford Site (Wash.)
关键词: Technetium 99;    Testing;    Transport;    Hydrology;    Geology;   
DOI  :  10.2172/881671
RP-ID  :  WMP-27397 Rev 1
RP-ID  :  DE-AC06-96RL13200
RP-ID  :  881671
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The Hanford Site End State Vision document (DOE/RL-2003-59) states: ''There should be an aggressive plan to develop technology for remediation of the contamination that could get to the groundwater (particularly the technetium [{sup 99}Tc])''. In addition, there is strong support from the public and regulatory agencies for the above statement, with emphasis on investigation of treatment alternatives. In July 2004, PNNL completed a preliminary evaluation of remediation technologies with respect to their effectiveness and implementability for immobilization of {sup 99}Tc beneath the BC Cribs in the 200 West Area (Truex, 2004). As a result of this evaluation, PNNL recommended treatability testing of in situ soil desiccation, because it has the least uncertainty of those technologies evaluated in July 2004 (Treatability Test Outline, September 30, 2004). In 2005, DOE-RL and Fluor Hanford convened an independent technical panel to review alternative remediation technologies, including desiccation, at a three-day workshop in Richland, Washington. The panel was composed of experts in vadose-zone transport, infiltration control, hydrology, geochemistry, environmental engineering, and geology. Their backgrounds include employment in academia, government laboratories, industry, and consulting. Their review, presented in this document, is based upon written reports from Hanford, oral presentations from Hanford staff, and each panel members' years of experience in their particular field of expertise. The purpose of this report is to document the panel's evaluation of various treatment alternatives with potential for minimizing contaminant migration in the deep vadose zone at the Department of Energy Hanford Site. The panel was tasked with assessing the most viable and practical approach and making recommendations for testing. The evaluation of vadose-zone treatment alternatives was conducted to be broadly applicable at a variety of locations at Hanford. However, because of limitations of time, the panel was asked to focus on one example, {sup 99}Tc contamination below the BC Cribs and Trenches. It is well recognized that conditions at BC Cribs and Trenches are not the same as those at other Hanford locations, but it was selected so that the panel could develop an understanding of site conditions at one location. The recommendations in this report are not intended to address the regulatory decision process for this site.

【 预 览 】
附件列表
Files Size Format View
881671.pdf 28726KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:17次