科技报告详细信息
Items Supporting the Hanford Internal Dosimetry Program Implementation of the IMBA Computer Code
Carbaugh, Eugene H. ; Bihl, Donald E.
关键词: BIOASSAY;    I CODES;    DOSIMETRY;    QUALITY ASSURANCE;    VERIFICATION;    HANFORD RESERVATION;    RADIATION PROTECTION;   
DOI  :  10.2172/967011
RP-ID  :  PNNL-17993
PID  :  OSTI ID: 967011
Others  :  TRN: US0904241
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The Hanford Internal Dosimetry Program has adopted the computer code IMBA (Integrated Modules for Bioassay Analysis) as its primary code for bioassay data evaluation and dose assessment using methodologies of ICRP Publications 60, 66, 67, 68, and 78. The adoption of this code was part of the implementation plan for the June 8, 2007 amendments to 10 CFR 835. This information release includes action items unique to IMBA that were required by PNNL quality assurance standards for implementation of safety software. Copie of the IMBA software verification test plan and the outline of the briefing given to new users are also included.

【 预 览 】
附件列表
Files Size Format View
RO201705180002880LZ 623KB PDF download