科技报告详细信息
Corporate Functional Management Evaluation of the LLNL Radiation Safety Organization
Sygitowicz, L S
关键词: ALARA;    BIOASSAY;    CALIBRATION;    DOCUMENTATION;    DOSEMETERS;    DOSIMETRY;    EVALUATION;    FUNCTIONALS;    IMPLEMENTATION;    LAWRENCE LIVERMORE NATIONAL LABORATORY;    MANAGEMENT;    PERSONNEL;    RADIATION PROTECTION;    RADIATIONS;   
DOI  :  10.2172/928527
RP-ID  :  LLNL-TR-402619
PID  :  OSTI ID: 928527
Others  :  TRN: US200812%%499
学科分类:社会科学、人文和艺术(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

A Corporate Assess, Improve, and Modernize review was conducted at Lawrence Livermore National Laboratory (LLNL) to evaluate the LLNL Radiation Safety Program and recommend actions to address the conditions identified in the Internal Assessment conducted July 23-25, 2007. This review confirms the findings of the Internal Assessment of the Institutional Radiation Safety Program (RSP) including the noted deficiencies and vulnerabilities to be valid. The actions recommended are a result of interviews with about 35 individuals representing senior management through the technician level. The deficiencies identified in the LLNL Internal Assessment of the Institutional Radiation Safety Program were discussed with Radiation Safety personnel team leads, customers of Radiation Safety Program, DOE Livermore site office, and senior ES&H management. There are significant issues with the RSP. LLNL RSP is not an integrated, cohesive, consistently implemented program with a single authority that has the clear roll and responsibility and authority to assure radiological operations at LLNL are conducted in a safe and compliant manner. There is no institutional commitment to address the deficiencies that are identified in the internal assessment. Some of these deficiencies have been previously identified and corrective actions have not been taken or are ineffective in addressing the issues. Serious funding and staffing issues have prevented addressing previously identified issues in the Radiation Calibration Laboratory, Internal Dosimetry, Bioassay Laboratory, and the Whole Body Counter. There is a lack of technical basis documentation for the Radiation Calibration Laboratory and an inadequate QA plan that does not specify standards of work. The Radiation Safety Program lack rigor and consistency across all supported programs. The implementation of DOE Standard 1098-99 Radiological Control can be used as a tool to establish this consistency across LLNL. The establishment of a site wide ALARA Committee and administrative control levels would focus attention on improved processes. Currently LLNL issues dosimeters to a large number of employees and visitors that do not enter areas requiring dosimetry. This includes 25,000 visitor TLDs per year. Dosimeters should be issued to only those personnel who enter areas where dosimetry is required.

【 预 览 】
附件列表
Files Size Format View
RO201705180002331LZ 119KB PDF download
  文献评价指标  
  下载次数:21次 浏览次数:71次