科技报告详细信息
Results of the Excreta Bioassay Quality Control Program For April 1, 2006 Through March 31, 2007
Antonio, Cheryl L.
关键词: FECES;    BIOASSAY;    DETECTION;    DOSIMETRY;    QUALITY CONTROL;    TRITIUM;    URANIUM;    URINE;    STRONTIUM;    PLUTONIUM;    AMERICIUM Excreta Bioassay;    Urine Analyses;    Fecal Analyses;   
DOI  :  10.2172/926108
RP-ID  :  PNNL-17358
PID  :  OSTI ID: 926108
Others  :  TRN: US0802501
学科分类:化学(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
A total of 66 urine samples, 6 blank fecal and 6 spiked artificial fecal samples were submitted during the report period (April 1, 2006 through March 31, 2007) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for tritium, Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.7% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 36% of the analyses processed by GEL during the second year of this contract were quality control samples. GEL tested the performance of 16 radioisotopes, all of which met or exceeded the specifications in the Statement of Work. IDP concluded that GEL was performing well for all analyses tested, and concerns identified earlier were satisfactorily resolved.
【 预 览 】
附件列表
Files Size Format View
RO201705180002579LZ 2730KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:32次