Joseph Rovani ; John Schabron
关键词: BENZOIC ACID;    CHROMATOGRAPHY;    DETECTION;    HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY;    MASS SPECTROSCOPY;    OIL FIELDS;    PERFORMANCE;    SENSITIVITY;    WATER;   
DOI  :  10.2172/993825
RP-ID  :  None
PID  :  OSTI ID: 993825
Others  :  TRN: US201101%%231
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

A low detection limit analytical method was developed to measure a suite of benzoic acid and fluorinated benzoic acid compounds intended for use as tracers for enhanced oil recovery operations. Although the new high performance liquid chromatography separation successfully measured the tracers in an aqueous matrix at low part per billion levels, the low detection limits could not be achieved in oil field water due to interference problems with the hydrocarbon-saturated water using the system's UV detector. Commercial instrument vendors were contacted in an effort to determine if mass spectrometry could be used as an alternate detection technique. The results of their work demonstrate that low part per billion analysis of the tracer compounds in oil field water could be achieved using ultra performance liquid chromatography mass spectrometry.