科技报告详细信息
Field Evaluation of Highly Insulating Windows in the Lab Homes: Winter Experiment
Parker, Graham B. ; Widder, Sarah H. ; Bauman, Nathan N.
关键词: AIR;    DATA ANALYSIS;    EVALUATION;    GLASS;    HEAT GAIN;    HEATING;    OCCUPANTS;    PERFORMANCE;    ROOFS;    SEASONS;    WALLS;    WINDOWS;    ENERGY EFFICIENCY Lab Homes;    windows;    energy performance;    metering;   
DOI  :  10.2172/1046331
RP-ID  :  PNNL-21524
PID  :  OSTI ID: 1046331
Others  :  Other: BT0101000
Others  :  TRN: US201215%%440
学科分类:能源(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
This field evaluation of highly insulating windows was undertaken in a matched pair of 'Lab Homes' located on the Pacific Northwest National Laboratory (PNNL) campus during the 2012 winter heating season. Improving the insulation and solar heat gain characteristics of a home's windows has the potential to significantly improve the home's building envelope and overall thermal performance by reducing heat loss (in the winter), and cooling loss and solar heat gain (in the summer) through the windows. A high quality installation and/or window retrofit will also minimize or reduce air leakage through the window cavity and thus also contribute to reduced heat loss in the winter and cooling loss in the summer. These improvements all contribute to decreasing overall annual home energy use. Occupant comfort (non-quantifiable) can also be increased by minimizing or eliminating the cold 'draft' (temperature) many residents experience at or near window surfaces that are at a noticeably lower temperature than the room air temperature. Lastly, although not measured in this experiment, highly insulating windows (triple-pane in this experiment) also have the potential to significantly reduce the noise transmittance through windows compared to standard double-pane windows. The metered data taken in the Lab Homes and data analysis presented here represent 70 days of data taken during the 2012 heating season. As such, the savings from highly insulating windows in the experimental home (Lab Home B) compared to the standard double-pane clear glass windows in the baseline home (Lab Home A) are only a portion of the energy savings expected from a year-long experiment that would include a cooling season. The cooling season experiment will take place in the homes in the summer of 2012, and results of that experiment will be reported in a subsequent report available to all stakeholders.
【 预 览 】
附件列表
Files Size Format View
RO201704190002901LZ 3275KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:22次