科技报告详细信息
Hafnium Resonance Parameter Analysis Using Neutron Capture and Transmission Experiments
Trbovich, M J ; Barry, D P ; Slovacek, R E ; Danon, Y ; Block, R C ; Francis, N C ; Lubert, M ; Burke, J A ; Drindak, N J ; Lienweber, G ; Ballad, R
关键词: ACCURACY;    CAPTURE;    CROSS SECTIONS;    DATA ANALYSIS;    GLASS;    HAFNIUM;    HAFNIUM ISOTOPES;    LINEAR ACCELERATORS;    MULTIPLICITY;    NEUTRONS;    REACTOR PHYSICS;    RESONANCE;    RESONANCE INTEGRALS;    SATURATION;    ZIRCONIUM;   
DOI  :  10.2172/903190
RP-ID  :  LM-07K004
PID  :  OSTI ID: 903190
Others  :  TRN: US0703584
学科分类:工程和技术(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The focus of this work is to determine the resonance parameters for stable hafnium isotopes in the 0.005 - 200 eV region, with special emphasis on the overlapping {sup 176}Hf and {sup 178}Hf resonances near 8 eV. Accurate hafnium cross sections and resonance parameters are needed in order to quantify the effects of hafnium found in zirconium, a metal commonly used in reactors. The accuracy of the cross sections and the corresponding resonance parameters used in current nuclear analysis tools are rapidly becoming the limiting factor in reducing the overall uncertainty on reactor physics calculations. Experiments measuring neutron capture and transmission are routinely performed at the Rensselaer Polytechnic Institute (RPI) LINAC using the time-of flight technique. {sup 6}Li glass scintillation detectors were used for transmission experiments at flight path lengths of 15 and 25 m, respectively. Capture experiments were performed using a sixteen section NaI multiplicity detector at a flight path length of 25 m. These experiments utilized several thicknesses of metallic and isotope-enriched liquid Hf samples. The liquid Hf samples were designed to provide information on the {sup 176}Hf and {sup 178}Hf contributions to the 8 eV doublet without saturation. Data analyses were performed using the R-matrix Bayesian code SAMMY. A combined capture and transmission data analysis yielded resonance parameters for all hafnium isotopes from 0.005 - 200 eV. Additionally, resonance integrals were calculated, along with errors for each hafnium isotope, using the NJOY and INTER codes. The isotopic resonance integrals calculated were significantly different than previous values. The {sup 176}Hf resonance integral, based on this work, is approximately 73% higher than the ENDF/B-VI value. This is due primarily to the changes to resonance parameters in the 8 eV resonance, the neutron width presented in this work is more than twice that of the previous value. The calculated elemental hafnium resonance integral however, changed very little.

【 预 览 】
附件列表
Files Size Format View
RO201705190002768LZ 502KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:22次