科技报告详细信息
241-AZ Tank Farm Construction Extent of Condition Review for Tank Integrity
Barnes, Travis J. ; Boomer, Kayle D. ; Gunter, Jason R. ; Venetz, Theodore J.
关键词: DST;    241-AZ Tank Farm;    leak;    tank construction;    extent of condition;   
DOI  :  10.2172/1089516
RP-ID  :  RPP-RPT-54818 Rev 0
PID  :  OSTI ID: 1089516
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This report provides the results of an extent of condition construction history review for tanks 241-AZ-101 and 241-AZ-102. The construction history of the 241-AZ tank farm has been reviewed to identify issues similar to those experienced during tank AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank AY-102 as the comparison benchmark. In the 241-AZ tank farm, the second DST farm constructed, both refractory quality and tank and liner fabrication were improved.

【 预 览 】
附件列表
Files Size Format View
RO201704180002210LZ 16774KB PDF download