Review of Test Procedure for Determining HSPFs of Residential Variable-Speed Heat Pumps
Rice, C. Keith1  Munk, Jeffrey D.1  Shrestha, Som S.1 
[1] Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
关键词: heat pump;    variable-speed;    HSPF;    residential;    ratings;   
DOI  :  10.2172/1223081
RP-ID  :  ORNL/TM--2015/387
PID  :  OSTI ID: 1223081
Others  :  Other: BT0400000
Others  :  CEBT002
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This report reviews the suitability of the existing Heating Seasonal Performance Factor (HSPF) ratings and testing requirements for the current generation of variable-speed (VS) air-source heat pumps. Recent field test results indicate larger discrepancies between rated HSPF and field-observed HSPF for VS models than for single-speed models in the same houses. These findings suggest that the heating season test and ratings procedure should be revisited for VS heat pumps. The ratings and testing procedures are described in ANSI/AHRI 210/240 (2008) for single-speed, two-capacity, and variable-speed units. Analysis of manufacturer and independent test performance data on VS units reveals why the current VS testing/ratings procedure results in overly optimistic HSPF ratings for some VS units relative to other types of heat pumps. This is due to a combination of extrapolation of low speed test data beyond the originally anticipated ambient temperature operating range and the constraints of unit controls, which prevent low speed operation over the range of ambient temperatures assumed in the procedure for low speed. As a result, the HSPFs of such units are being overpredicted relative to those for single- and two-capacity designs. This overprediction has been found to be significantly reduced by use in the HSPF ratings procedure of an alternative higher-load heating load line, described in a companion report (Rice et al., 2015).

【 预 览 】
附件列表
Files Size Format View
1396KB PDF download
  文献评价指标  
  下载次数:17次 浏览次数:31次