科技报告详细信息
Systems Evaluation at the Cool Energy House
Williamson, J.1  Puttagunta, S.1 
[1]Steven Winter Associates, Inc., Norwalk, CT (United States)
关键词: heat pump water heater;    dehumidifiers;    air conditioning;    latent;    sensible;    cooling;    comfort;    relative humidity;    moisture content;    thermostat set point;    humid;    air source heat pumps;    dehumidification;    hot water;    heat pump;    single family attached;    single family detached;    residential;    residential buildings;    Consortium for Advanced Residential Buildings (CARB);    Building America;   
DOI  :  10.2172/1260117
RP-ID  :  NREL/SR--5500-58713
RP-ID  :  DOE/GO--102013-3942
PID  :  OSTI ID: 1260117
学科分类:能源(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
Steven Winter Associates, Inc. (SWA) monitored several advanced mechanical systems within a 2012 deep energy retrofitted home in the small Orlando suburb of Windermere, FL. This report provides performance results of one of the home's heat pump water heaters (HPWH) and the whole-house dehumidifier (WHD) over a six month period. In addition to assessing the energy performance of these systems,this study sought to quantify potential comfort improvements over traditional systems. This information is applicable to researchers, designers, plumbers, and HVAC contractors. Though builders and homeowners can find useful information within this report, the corresponding case studies are a likely better reference for this audience.
【 预 览 】
附件列表
Files Size Format View
RO201704180001683LZ 1492KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:36次