Field Monitoring Protocol. Heat Pump Water Heaters
Sparn, B.1  Earle, L.1  Christensen, D.1  Maguire, J. 
[1] National Renewable Energy Lab. (NREL), Golden, CO (United States)
关键词: NREL;    heat pump water heater;    HPWH;    field test;    residential;    residential buildings;    National Renewable Energy Laboratory;    Building America;   
DOI  :  10.2172/1219905
RP-ID  :  NREL/TP--5500-57698
PID  :  OSTI ID: 1219905
Others  :  Other: 6093
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

【 预 览 】
附件列表
Files Size Format View
RO201704180004311LZ 2828KB PDF download