科技报告详细信息
Review Facility Design Drawings M3FT-16LA040105011 - Safeguards and Security by Design for Used Fuel Extended Storage: 1.02.04.01.05 FT ??? 16LA04010501
Scherer, Carolynn P.1  Rauch, Eric Benton1 
[1] Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
关键词: DRY STORAGE;    AWAY-FROM-REACTOR STORAGE;    DOMESTIC SAFEGUARDS;    STORAGE FACILITIES;    DESIGN;    ENGINEERING DRAWINGS;    SECURITY;    ACCOUNTING;    CONTROL Nuclear Fue;   
DOI  :  10.2172/1248118
RP-ID  :  LA-UR--16-22523
PID  :  OSTI ID: 1248118
Others  :  TRN: US1601258
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This work package focuses on developing Best Practices for the design of security for, and domestic safeguarding (e.g. MC&A) of, a pilot-scale independent spent/used fuel storage facility consistent with conceptual design efforts in Nuclear Fuels Storage and Transportation (NFST) and Used Fuel Disposal (UFD) campaigns. This is a review of the basic design of the facility to determine a candidate list of accounting and control requirements that could be considered for safeguards and security purposes.

【 预 览 】
附件列表
Files Size Format View
1764KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:19次