科技报告详细信息
Analytical Results from Routine DSSHT and SEHT Monthly Samples
Peters, T. B.1 
[1] Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)
关键词: MCU;   
DOI  :  10.2172/1305140
RP-ID  :  SRNL-STI--2016-00384
PID  :  OSTI ID: 1305140
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the ???microbatches??? of Integrated Salt Disposition Project (ISDP) Salt Batch (???Macrobatch???) 8B have been analyzed for 238Pu, 90Sr, 137Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU) continue to show more than adequate Pu and Sr removal for times when monosodium titanate (MST) is used. Even with no MST strike being performed there exists some small Pu and Sr removal, likely from filtration of fines containing these elements. The Cs removal continues to be excellent, with decontamination factors (DF) averaging 16,400. The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior. SRNL recommends that a sample of the strip feed be analyzed for cation and anion content if a further decline in boron concentration is noted in future SEHT samples.

【 预 览 】
附件列表
Files Size Format View
306KB PDF download