期刊论文详细信息
JOURNAL OF BIOMECHANICS 卷:46
Application of a mechanobiological simulation technique to stents used clinically
Article
Boyle, Colin J.1  Lennon, Alex B.1,2  Prendergast, Patrick J.1 
[1] Trinity Coll Dublin, Sch Engn, Trinity Ctr Bioengn, Dublin, Ireland
[2] Queens Univ Belfast, Sch Mech & Aerosp Engn, Belfast BT7 1NN, Antrim, North Ireland
关键词: Mechanobiology;    Restenosis;    Stent design;    Lattice-based models;    SMC behaviour;    Inflammation;   
DOI  :  10.1016/j.jbiomech.2012.12.014
来源: Elsevier
PDF
【 摘 要 】

Many cardiovascular diseases are characterised by the restriction of blood flow through arteries. Stents can be expanded within arteries to remove such restrictions; however, tissue in-growth into the stent can lead to restenosis. In order to predict the long-term efficacy of stenting, a mechanobiological model of the arterial tissue reaction to stress is required. In this study, a computational model of arterial tissue response to stenting is applied to three clinically relevant stent designs. We ask the question whether such a mechanobiological model can differentiate between stents used clinically, and we compare these predictions to a purely mechanical analysis. In doing so, we are testing the hypothesis that a mechanobiological model of arterial tissue response to injury could predict the long-term outcomes of stent design. Finite element analysis of the expansion of three different stent types was performed in an idealised, 3D artery. Injury was calculated in the arterial tissue using a remaining-life damage mechanics approach. The inflammatory response to this initial injury was modelled using equations governing variables which represented tissue-degrading species and growth factors. Three levels of inflammation response were modelled to account for inter-patient variability. A lattice-based model of smooth muscle cell behaviour was implemented, treating cells as discrete agents governed by local rules. The simulations predicted differences between stent designs similar to those found in vivo. It showed that the volume of neointima produced could be quantified, providing a quantitative comparison of stents. In contrast, the differences between stents based on stress alone were highly dependent on the choice of comparison criteria. These results show that the choice of stress criteria for stent comparisons is critical. This study shows that mechanobiological modelling may provide a valuable tool in stent design, allowing predictions of their long-term efficacy. The level of inflammation was shown to affect the sensitivity of the model to stent design. If this finding was verified in patients, this could suggest that high-inflammation patients may require alternative treatments to stenting. (c) 2013 Elsevier Ltd. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jbiomech_2012_12_014.pdf 1415KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:0次