期刊论文详细信息
JOURNAL OF POWER SOURCES 卷:174
Effects of separator breakdown on abuse response of 18650 Li-ion cells
Article; Proceedings Paper
Roth, E. P.1  Doughty, D. H.1  Pile, D. L.1 
[1] Sandia Natl Labs, Albuquerque, NM 87185 USA
关键词: Li-ion;    separator;    shutdown;    overcharge;    thermal runaway;   
DOI  :  10.1016/j.jpowsour.2007.06.163
来源: Elsevier
PDF
【 摘 要 】

The thermal abuse tolerance of Li-ion cells depends not only on the stability of the active materials in the anode and cathode but also on the stability of the separator which prevents direct interaction between these electrodes. Separator response has been measured as a function of temperature and high voltage both for isolated materials and in full 18650 cells. Separators with different compositions and properties were measured to determine the effect of separator melt integrity on cell response under abusive conditions. These studies were performed as part of the U.S. Department of Energy (DOE) Advanced Technology Development (ATD) Program. Published by Elsevier B.V.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jpowsour_2007_06_163.pdf 1080KB PDF download
  文献评价指标  