期刊论文详细信息
TALANTA 卷:222
Evaluation of Mass Sensitive Micro-Array biosensors for their feasibility in multiplex detection of low molecular weight toxins using mycotoxins as model compounds
Article
Nolan, P.1  Auer, S.2  Spehar, A.2  Oplatowska-Stachowiak, M.1  Campbell, K.1 
[1] Queens Univ Belfast, Inst Global Food Secur, Sch Biol Sci, 19 Chlorine Gardens, Belfast BT9 5DL, Antrim, North Ireland
[2] BioMensio Ltd, Hermiankatu 6-8H, Tampere 33720, Finland
关键词: Mycotoxin;    Immunoassay;    Mass sensitive microarray biosensor;    On-site detection;    Rapid detection method;    Multiplex detection;   
DOI  :  10.1016/j.talanta.2020.121521
来源: Elsevier
PDF
【 摘 要 】

Mycotoxins produced by Fusarium species including trichothecenes, zearalenone and fumonisins, can co-contaminate food and feed throughout the supply chain, including cereal grains and animal feeds. There is an increasing demand to enhance global food security by improving the monitoring of mycotoxins throughout our food supply chain. For time and cost-efficient analysis, rapid tests capable of detecting multiple toxins from a single sample are ideal. Considering these current trends in mycotoxin testing, this project examined the feasibility of using both a portable and non-portable mass-based biosensor for multiplex mycotoxin detection. The biosensor was a mass sensitive microarray (MSMA) which consisted of 4 x 16 miniaturized mass sensitive transducer pixels based on solidly mounted resonator (SMR) technology. Functionalisation of individual pixels on the sensor surface using nano-spotting technology for the simultaneous and semi-quantitative detection of three regulated mycotoxins: T2-toxin (T2) zearalenone (ZEN), and fumonisin B1 (FumB1) was examined. With the integration of portable and non-portable microfluidic devices for antibody and standard sample injections, competitive inhibition assays were developed followed by singleplex and multiplex calibration curves. The characteristics and performance of the MSMA were evaluated including sensitivity which was determined as the concentration causing 50% inhibition. Sensitivity of singleplex assays using the portable microfluidic device (PMD) were 1.3 ng/ml, 2.0 ng/ml and 6.8 ng/ml for T2, FumB1 and ZEN, respectively. Sensitivity of the multiplex assay again using the PMD was 6.1 ng/ml, 3.6 ng/ml and 2.4 ng/ml for T2, FumB1 and ZEN, respectively. The PMD was an easy to use and highly sensitive screening tool which has been demonstrated for the multiplex detection of three regulated mycotoxins. Analysis was in real time and results were fully digital. Since detection of analytes was by mass it was both a label-free and cost-efficient method proposed method of analysis for mycotoxins.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_talanta_2020_121521.pdf 4419KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:1次