期刊论文详细信息
BMC Cardiovascular Disorders
Does stress perfusion imaging improve the diagnostic accuracy of late gadolinium enhanced cardiac magnetic resonance for establishing the etiology of heart failure?
Research Article
Florence Y. Lai1  Iain B. Squire1  Daniel J. Swarbrick1  Jeffrey Khoo1  Abishek Shetye1  Jayanth R. Arnold1  Gaurav S. Gulsin1  Eylem Levelt1  Gerry P. McCann1 
[1] Department of Cardiovascular Sciences, University of Leicester, Glenfield Hospital, Groby Road, LE3 9QP, Leicester, UK;The NIHR Leicester Cardiovascular Biomedical Research Unit, Glenfield Hospital, Leicester, UK;
关键词: Cardiovascular magnetic resonance;    Heart failure;    Late gadolinium enhancement;    Adenosine stress perfusion;    Non-ischemic cardiomyopathy;   
DOI  :  10.1186/s12872-017-0529-y
 received in 2016-12-20, accepted in 2017-03-31,  发布年份 2017
来源: Springer
PDF
【 摘 要 】

BackgroundLate gadolinium enhanced cardiovascular magnetic resonance (LGE-CMR) has excellent specificity, sensitivity and diagnostic accuracy for differentiating between ischemic cardiomyopathy (ICM) and non-ischemic dilated cardiomyopathy (NICM). CMR first-pass myocardial perfusion imaging (perfusion-CMR) may also play role in distinguishing heart failure of ischemic and non-ischemic origins, although the utility of additional of stress perfusion imaging in such patients is unclear. The aim of this retrospective study was to assess whether the addition of adenosine stress perfusion imaging to LGE-CMR is of incremental value for differentiating ICM and NICM in patients with severe left ventricular systolic dysfunction (LVSD) of uncertain etiology.MethodsWe retrospectively identified 100 consecutive adult patients (median age 69 years (IQR 59–73)) with severe LVSD (mean LV EF 26.6 ± 7.0%) referred for perfusion-CMR to establish the underlying etiology of heart failure. The cause of heart failure was first determined on examination of CMR cine and LGE images in isolation. Subsequent examination of complete adenosine stress perfusion-CMR studies (cine, LGE and perfusion images) was performed to identify whether this altered the initial diagnosis.ResultsOn LGE-CMR, 38 patients were diagnosed with ICM, 46 with NICM and 16 with dual pathology. With perfusion-CMR, there were 39 ICM, 44 NICM and 17 dual pathology diagnoses. There was excellent agreement in diagnoses between LGE-CMR and perfusion-CMR (κ 0.968, p<0.001). The addition of adenosine stress perfusion images to LGE-CMR altered the diagnosis in only two of the 100 patients.ConclusionThe addition of adenosine stress perfusion-CMR to cine and LGE-CMR provides minimal incremental diagnostic yield for determining the etiology of heart failure in patients with severe LVSD.

【 授权许可】

CC BY   
© The Author(s). 2017

【 预 览 】
附件列表
Files Size Format View
RO202311105544639ZK.pdf 1243KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  文献评价指标  
  下载次数:0次 浏览次数:2次