Malaria Journal
Development and performance evaluation of a novel immunofluorescence chromatographic assay for histidine-rich protein 2 of Plasmodium falciparum
Research
Emmanuel E. Dzakah1  Jihua Wang2  Yongping Huang2  Wenmei Li2  Xiaochun Luo3  Mingquan Xie3  Keren Kang4 
[1] Department of Molecular Biology and Biotechnology, School of Biological Sciences, College of Agriculture and Natural Sciences, University of Cape Coast, Cape Coast, Ghana;National Engineering Laboratory of Rapid Diagnostic Tests, Guangzhou Wondfo Biotech Co Ltd, 510663, Guangzhou, Guangdong, China;School of Bioscience and Bioengineering, South China University of Technology, 510006, Guangzhou, Guangdong, China;School of Bioscience and Bioengineering, South China University of Technology, 510006, Guangzhou, Guangdong, China;National Engineering Laboratory of Rapid Diagnostic Tests, Guangzhou Wondfo Biotech Co Ltd, 510663, Guangzhou, Guangdong, China;
关键词: Plasmodium falciparum;    Immunofluorescence chromatographic assay;    Histidine-rich protein 2;    Rapid diagnostic test;   
DOI  :  10.1186/s12936-015-0740-1
 received in 2015-02-03, accepted in 2015-05-20,  发布年份 2015
来源: Springer
PDF
【 摘 要 】

BackgroundThe low sensitivity and specificity of Plasmodium falciparum diagnostic tests pose a serious health threat to people living in endemic areas. The objective of the study was to develop a rapid assay for the detection of histidine-rich protein 2 (HRP2) of P. falciparum in whole blood by immunofluorescence chromatographic technology.MethodsA total of 1163 positive and negative blood samples were screened. The double-antibody sandwich assay was used to establish the kit and its performance was evaluated for sensitivity, specificity, accuracy, precision, stability, and clinical effectiveness.ResultsThe cut-off level of detection of the kit was 25 parasites/μl. Common interfering substances in human blood specimens, such as bilirubin, triglyceride and cholesterol had no significant effect on HRP2 antigen detection. The precision of the kit was run with different concentration of standard calibrators and the values were less than 10 %. The performance of this diagnostic kit in the detection of the calibrators has shown that a shelf life of about 12 months gives a more reliable result. Among clinical samples tested, the HRP2 test kit and the reference products had good coincidence rate in a parallel experiment and this test kit had a more sensitive detecting level to the target protein than the reference kits used in this study. The specificity and sensitivity for this test were 99.6 % (800/803) and 99.7 % (1160/1163), respectively.ConclusionsA novel HRP2 immunofluorescence detection method was developed in this study. Overall performance evaluation indicated that the kit has a rapid, high sensitivity and on-spot method for detecting P. falciparum.

【 授权许可】

CC BY   
© Kang et al. 2015

【 预 览 】
附件列表
Files Size Format View
RO202311104767858ZK.pdf 1218KB PDF download
12944_2023_1932_Article_IEq1.gif 1KB Image download
Fig. 12 729KB Image download
【 图 表 】

Fig. 12

12944_2023_1932_Article_IEq1.gif

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  文献评价指标  
  下载次数:2次 浏览次数:1次