期刊论文详细信息
BMC Musculoskeletal Disorders
Computer-assisted total knee arthroplasty using mini midvastus or medial parapatellar approach technique
Research Article
Jacobus J. Arts1  Peter Feczko1  Lutz Engelmann2  David Campbell3 
[1] Department Orthopaedic Surgery, Research School Capri, Maastricht University Medical Centre, P. Debyelaan 25, 6229 HX, Maastricht, The Netherlands;Heinrich-Braun-Krankenhaus Zwickau, Städtisches Klinikum, Zwickau, Germany;Repatriation General Hospital, Adelaide, Australia;
关键词: Total knee arthroplasty;    Navigation;    Minimally invasive surgery;    Blood loss;    Accuracy;   
DOI  :  10.1186/s12891-016-0872-7
 received in 2015-01-29, accepted in 2016-01-05,  发布年份 2016
来源: Springer
PDF
【 摘 要 】

BackgroundDespite the growing evidence in the literature there is still a lack of consensus regarding the use of minimally invasive surgical technique (MIS) in total knee arthroplasty (TKA).MethodsA prospective, randomized, international multicentre trial including 69 patients was performed to compare computer-assisted TKA (CAS-TKA) using either mini-midvastus (MIS group) or standard medial parapatellar approach (conventional group).Patients from 3 centers (Maastricht, Zwickau, Adelaide) with end-stage osteoarthritis of the knee were randomized to either an MIS group with dedicated instrumentation or a conventional group to receive cruciate retaining CAS-TKA without patella resurfacing. The primary outcome was to compare post operative pain and range of motion (ROM). The secondary outcome was to measure the duration of surgery, blood loss, chair rise test, quadriceps strength, anterior knee pain, Knee Society Score (KSS),WOMAC scores, mechanical leg axis and component alignment.ResultsPatients in the MIS group (3.97 ± 2.16) had significant more pain at 2 weeks than patients in the conventional group (2.77 ± 1.43) p = 0.003. There was no significant difference in any of the other primary outcome parameters. Surgery time was significantly longer (p < 0.001) and there were significantly higher blood loss (p = 0.002) in the MIS group as compared to the conventional group. The difference of the mean mechanical leg alignment between the groups was not statistically significant (–0.43° (95 % CI –1.50 – 0.64); p = 0.43).There was no significant difference of component alignment between the two surgical groups with respect to flexion/extension (p = 0.269), varus/valgus (p = 0.653) or rotational alignment (p = 0.485) of the femur component and varus valgus alignment (p = 0.778) or posterior slope (p = 0.164) of the tibial component.ConclusionThere was no advantage of the MIS approach compared to a conventional approach CAS-TKA in any of the primary outcome measurements assessed, however the MIS approach was associated with longer surgical time and greater blood loss. MIS-TKA in combination with computer navigation is safe in terms of implant positioning.Trial registration numberClinicalTrials.gov NCT02625311 8 December 2015

【 授权许可】

CC BY   
© Feczko et al. 2016

【 预 览 】
附件列表
Files Size Format View
RO202311094846960ZK.pdf 892KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  • [42]
  • [43]
  • [44]
  • [45]
  • [46]
  • [47]
  • [48]
  • [49]
  • [50]
  • [51]
  • [52]
  • [53]
  • [54]
  • [55]
  • [56]
  • [57]
  • [58]
  • [59]
  • [60]
  • [61]
  文献评价指标  
  下载次数:1次 浏览次数:0次