| Comparison of cone beam computed tomography and plane radiographs of radial fractures as a basis for radiographical measurements | |
| Research Article | |
| Kristian Bry1  Mika Koivikko1  Liisa Kerttula1  Mika Kortesniemi2  | |
| [1] Bridge Hospital, HUS, Haartmaninkatu 4, 00029, Helsinki, Finland;Department of Radiology, Helsinki Medical Imaging Center, Helsinki University Hospital and University of Helsinki, 00029, Helsinki, Finland;Department of Radiology, Medical Imaging Center, University of Helsinki and Helsinki University Hospital, P.O.Box 263, HUS, 00029, Helsinki, Finland; | |
| 关键词: Cone-beam computed tomography; Radiography; Radius fractures; | |
| DOI : 10.1186/s12880-023-01093-4 | |
| received in 2021-11-25, accepted in 2023-08-31, 发布年份 2023 | |
| 来源: Springer | |
PDF
|
|
【 摘 要 】
BackgroundThe purpose of this study was to determine whether radiological measurements of radial fracture position made in cone beam computed tomography (CBCT) projection images are comparable to those made on traditional radiographs and could potentially substitute them.MethodsSixteen patients with fractures of the distal radius referred for radiographs were recruited for an additional CBCT scan which was performed immediately afterwards. Projection images and volumetric data were saved from the CBCT scans. Measurements of ulnar variance, radial inclination and volar tilt were made from all three sets of images.ResultsAgreement of projection image based measurements with radiographs was nearly as good as as the agreement of cross sectional image measurements with radiographs. The average difference between the results for projection images and radiographs were -1.2 mm (SD 1.9 mm), for radial inclination 0.7° (SD 2.9°) and for volar tilt 1.9° (SD 5.6°).ConclusionDifferences between radiological measurements between the modalities studied are small and projection images could be used for the assessment of distal radial fractures.
【 授权许可】
CC BY
© BioMed Central Ltd., part of Springer Nature 2023
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202310117506188ZK.pdf | 1301KB | ||
| Fig. 1 | 135KB | Image | |
| 13690_2023_1170_Article_IEq89.gif | 1KB | Image | |
| MediaObjects/12960_2023_858_MOESM4_ESM.doc | 50KB | Other | |
| MediaObjects/12894_2023_1317_MOESM5_ESM.csv | 12KB | Other | |
| 42004_2023_995_Article_IEq11.gif | 1KB | Image | |
| MediaObjects/12888_2023_5145_MOESM4_ESM.docx | 15KB | Other | |
| Fig. 1 | 996KB | Image | |
| Fig. 2 | 1420KB | Image |
【 图 表 】
Fig. 2
Fig. 1
42004_2023_995_Article_IEq11.gif
13690_2023_1170_Article_IEq89.gif
Fig. 1
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
PDF