期刊论文详细信息
BMC Oral Health
Could cone-beam computed tomography demonstrate the lateral accessory canals?
Research Article
Shu Liu1  Tiemei Wang1  Zitong Lin1  Menghuan Yao1  Shanhui Wen1  Min Zhu2  Yan Ji3 
[1] Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China;Department of Endodontics, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China;Department of Preventive Dentistry, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China;
关键词: Cone-beam computed tomography;    Canal staining and tooth clearing technique;    Mandibular incisor;    Root canal morphology;    Voxel size;    Radiation dose;    Radiography;   
DOI  :  10.1186/s12903-017-0430-1
 received in 2017-06-08, accepted in 2017-11-19,  发布年份 2017
来源: Springer
PDF
【 摘 要 】

BackgroundRecently, using cone-beam computed tomography (CBCT) to assess root canal morphology has become popular; however, few studies have examined its efficiency to assess the entire root canals, including the tiny lateral and accessory canals (LACs). This study aimed to assess the ability of CBCT to evaluate the root canal of mandibular incisors at three different scanning settings, compared with the canal staining and tooth clearing (CS) technique as the gold standard.MethodsCBCT images of 70 extracted mandibular incisors were taken using NewTom VG CBCT at high-resolution scan mode (HZ), zoom scan mode (ZS), and full scan mode (FS), with different scanning settings. A radiologist, a postgraduate student, and an endodontist assessed the root canal morphology in a blinded manner. The number of root canals (NC), canal configuration according to Vertucci’s classification (VC), and LACs were evaluated twice by each evaluator using the CBCT images, in comparison with CS. Comparisons of the differences were used the chi-square test, and the intra-evaluator and inter-evaluator agreement were used the Kappa statistics; the significance level was set at 0.05.ResultsThe voxel dimension of HZ, ZS and FS modes were 0.125 mm, 0.20 mm and 0.25 mm respectively, and the HZ mode had significant increased scanning doses. For NC, the diagnostic accuracy was >90% in all three modes, with no significant difference among the evaluators and modes. VC and LAC could only be evaluated in HZ mode. For VC, the accuracies were 97.1%, 94.3%, and 92.9% respectively, with no significant differences among the three evaluators. For LAC, the accuracies were 80.0%, 13.3%, and 33.3% respectively, and there were significant differences among the three evaluators. Intra-evaluator agreement was excellent, with the kappa values indicating “perfect” to “substantial” agreement. Inter-evaluator agreement was excellent for NC and VC; however, Kappa values could not be analyzed due to LACs detected were so variable.ConclusionsAs far as possible, the HZ mode should be chosen to demonstrate the root canal system, and partial LACs could be detected using this mode; however, the potential benefit of the diagnostic information must be weighed against the increased radiation dose.

【 授权许可】

CC BY   
© The Author(s). 2017

【 预 览 】
附件列表
Files Size Format View
RO202311094119021ZK.pdf 3007KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  文献评价指标  
  下载次数:30次 浏览次数:0次