期刊论文详细信息
The Korean Journal of Parasitology
An Evaluation of a New Quantitative Point-of Care Diagnostic to Measure Glucose-6-phosphate Dehydrogenase Activity
article
Young Yil Bahk1  Seong Kyu Ahn2  Heung Jin Jeon3  Byoung-Kuk Na4  Sung-Keun Lee5  Ho-Joon Shin6 
[1] Department of Biotechnology, College of Biomedical and Health Science, Konkuk University;Infectious Diseases Investigation Division, Jeonnam Institute of Public Health and Environment;Infection Control Convergence Research Center, Chungnam National University College of Medicine;Department of Parasitology and Tropical Medicine, Institute of Health Sciences, College of Medicine, Gyeongsang National University;Department of Pharmacology, Inha University School of Medicine, Incheon 22212;Department of Microbiology, Ajou University School of Medicine
关键词: G6PD deficiency;    mBFP;    diagnostics;    malaria treatment;    primaquine;   
DOI  :  10.3347/kjp.2022.60.4.281
学科分类:生物科学(综合)
来源: The Korean Society for Parasitology
PDF
【 摘 要 】

Malaria continues to be one of the most crucial infectious burdens in endemic areas worldwide, as well as for travelers visiting malaria transmission regions. It has been reported that 8-aminoquinolines are effective against the Plasmodium species, particularly primaquine, for anti-hypnozoite therapy in P. vivax malaria. However, primaquine causes acute hemolytic anemia in individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency. Therefore, G6PD deficiency testing should precede hypnozoite elimination with 8-aminoquinoline. Several point-of-care devices have been developed to detect G6PD deficiency. The aim of the present study was to evaluate the performance of a novel, quantitative G6PD diagnostics based on a metagenomic blue fluorescent protein (mBFP). We comparatively evaluated the sensitivity and specificity of the G6PD diagnostic modality with standard methods using 120 human whole blood samples. The G6PD deficiency was spectrophotometrically confirmed. The performance of the G6PD quantitative test kit was compared with that of a licensed control medical device, the G6PD strip. The G6PD quantitative test kit had a sensitivity of 95% (95% confidence interval (CI): 89.3–100%) and a specificity of 100% (95% CI: 94.3–100%). This study shows that the novel diagnostic G6PD quantitative test kit could be a cost-effective and time-efficient, and universally mandated screening tool for G6PD deficiency.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
RO202307070002561ZK.pdf 729KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:1次