期刊论文详细信息
Quantitative Imaging in Medicine and Surgery
Chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) quantification of transient ischemia using a combination method of 5-pool Lorentzian fitting and inverse Z-spectrum analysis
article
Lihong Zhang1  Chongxin Xu1  Zhen Li2  Junding Sun1  Xiaoli Wang2  Beibei Hou1  Yingcheng Zhao3 
[1] College of Computer Science and Technology , Henan Polytechnic University;Department of Medical Imaging, Weifang Medical University;Xi’an Key Lab of Radiomics and Intelligent Perception, School of Information Sciences and Technology , Northwest University
关键词: Chemical exchange saturation transfer (CEST);    acute stroke;    magnetization transfer ratio yielding rex (MTRRex);    5-pool Lorentzian fitting;   
DOI  :  10.21037/qims-22-420
学科分类:外科医学
来源: AME Publications
PDF
【 摘 要 】

Background: Chemical exchange saturation transfer (CEST) is a promising method for the detection of biochemical alterations in cancers and neurological diseases. However, the sensitivity of the currently existing quantitative method for detecting ischemia needs further improvement. Methods: To further improve the quantification of the CEST signal and enhance the CEST detection for ischemia, we used a quantitative analysis method that combines an inverse Z-spectrum analysis and a 5-pool Lorentzian fitting. Specifically, a 5-pool Lorentzian simulation was conducted with the following brain tissue parameters: water, amide (3.5 ppm), amine (2.2 ppm), magnetization transfer (MT), and nuclear Overhauser enhancement (NOE; –3.5 ppm). The parameters were first calculated offline and stored as the initial value of the Z-spectrum fitting. Then, the measured Z-spectrum with the peak value set to 0 was fitted via the stored initial value, which yielded the reference Z-spectrum. Finally, the difference between the inverse of the Z-spectrum and the inverse of the reference Z-spectrum was used as the CEST definite spectrum. Results: The simulation results demonstrated that the Z-spectra of the rat brain were well simulated by a 5-pool Lorentzian fitting. Further, the proposed method detected a larger difference than did either the saturation transfer difference or the 5-pool Lorentzian fitting, as demonstrated by simulations. According to the results of the cerebral ischemia rat model, the proposed method provided the highest contrast-to-noise ratio (CNR) between the contralateral and the ipsilateral striatum under various acquisition conditions. The results indicated that the difference of fitted amplitudes generated with a 5-pool Lorentzian fitting in amide at 3.5 ppm (6.04%±0.39%; 6.86%±0.39%) was decreased in a stroke lesion compared to the contralateral normal tissue. Moreover, the difference of the residual of inversed Z-spectra in which 5-pool Lorentzian fitting was used to calculate the reference Z-spectra (MTRRex5L) amplitudes in amide at 3.5 ppm (13.83%±2.20%, 15.69%±1.99%) was reduced in a stroke lesion compared to the contralateral normal tissue. Conclusions:MTRRex5L is predominantly pH-sensitive and is suitable for detecting tissue acidosis following an acute stroke.

【 授权许可】

All Rights reserved   

【 预 览 】
附件列表
Files Size Format View
RO202303290000731ZK.pdf 4446KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:0次