期刊论文详细信息
Quantitative Imaging in Medicine and Surgery
Application of a Markov chain Monte Carlo method for robust quantification in chemical exchange saturation transfer magnetic resonance imaging
article
Yingcheng Zhao1  Xiaoli Wang2  Yifei Wang1  Beilei Wang1  Lihong Zhang3  Xiao Wei1  Xiaowei He1 
[1] Xi’an Key Lab of Radiomics and Intelligent Perception, School of Information Sciences and Technology , Northwest University;Department of Medical Imaging, Weifang Medical University;College of Computer Science and Technology ,(Software College) , Henan Polytechnic University
关键词: Chemical exchange saturation transfer (CEST);    CEST effect quantification;    Bayesian inference;    Markov chain Monte Carlo (MCMC);   
DOI  :  10.21037/qims-22-313
学科分类:外科医学
来源: AME Publications
PDF
【 摘 要 】

Background: Chemical exchange saturation transfer (CEST) magnetic resonance imaging can provide surrogate biomarkers for disease diagnosis. However, endogenous CEST effects are always diluted and contaminated by competing effects, which results in unwanted signal contributions that lessen the specificity of CEST to underlying biochemical exchange processes. The aim of this study was to examine a method for the accurate quantification of CEST effects. Methods: A Markov chain Monte Carlo (MCMC)-based Bayesian inference approach was proposed to estimate the exchange parameters, and CEST effects could be fitted using these estimations. This approach was tested in Bloch simulation and ischemic stroke rat experiments, and its performance was evaluated using quantification maps and numerical metrics. Results: With 12 groups of simulations, the MCMC method achieved satisfactory fittings on both 2-pool and 5-pool models. The sum of squares error values and the root mean square error of the fitted Z-spectra were smaller than 10−3, and the coefficient of determination (R-squared) values were close to 1. The corresponding CEST quantification MTRRexCEST spectra were also well fitted and successfully separated the mixed CEST effects. The estimated parameters showed little bias relative to the ground truth, with errors between the true and estimated values of each parameter of less than 0.5%. In the animal experiments, MTRRexAmide fitted using the MCMC method showed obvious contrast between ischemic and contralateral regions at the early stage. Compared with other quantification methods, it displayed the highest contrast-to-noise ratios (3.9, 2.73, and 3.93) and the lowest coefficient of variation values (0.181, 0.2224, and 0.2897) in all three stroke periods. Conclusions: The MCMC method provided an efficient approach for parameter estimation and CEST effect quantification. The method may therefore be useful in achieving an accurate pathological diagnosis.

【 授权许可】

All Rights reserved   

【 预 览 】
附件列表
Files Size Format View
RO202303290000541ZK.pdf 3013KB PDF download
  文献评价指标  