期刊论文详细信息
Physics and Imaging in Radiation Oncology
Exploratory models comparing ethiodized oil-glue and gold fiducials for bladder radiotherapy image-guidance
Alexandra Berlangieri1  Nathan Lawrentschuk2  Vincent Khoo3  Kerryn Brown3  Farshad Foroudi3  Morikatsu Wada3  Trish Jenkins3  Colleen Berry3  Michael Chao3  Benjamin Harris3  Daryl Lim Joon3  Shomik Sengupta3  Rachel O'Meara3  Mark Tacey3  Brent Pitt3  Michal Schneider3  Angela Viotto3 
[1] Monash University, Department of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences, Wellington Rd, Clayton, Victoria 3800, Australia;Monash University, Department of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences, Wellington Rd, Clayton, Victoria 3800, Australia;Olivia Newton John Cancer Center, Radiation Oncology, 145 Studley Rd, Heidelberg, Victoria 3084, Australia;
关键词: Bladder cancer;    Prostate cancer;    Radiotherapy;    Glue fiducials;    Liquid fiducials;    Image-guided radiotherapy;   
DOI  :  
来源: DOAJ
【 摘 要 】

Background and purpose: Image-guidance with fiducials has been shown to improve pelvic radiotherapy outcome. However, bladder fiducials using ethiodized oil (EO) alone can disperse widely, and gold causes Computed Tomography scan (CT) metal artifacts. The study's purpose was to investigate the ability to deliver EO-tissue glue fiducials and compare them to gold for bladder radiotherapy image guidance. Materials and methods: A fluid-filled porcine bladder model was used to assess the ability to cystoscopically inject visible EO glue fiducials into the submucosa. We then transferred the bladders into a porcine pelvis for imaging and compared them to gold fiducials using CT, Cone Beam CT (CBCT), and kilovoltage (KV) planar views. A tissue-equivalent phantom was utilized to analyze the CT number Hounsfield Unit (HU) characteristics and artifacts of the glue and gold fiducials. Percentile ranges and normal tissue voxel percentages of the subsequent CT number voxel histogram from a 2 cm sphere surrounding the fiducial was used to characterize the artifact. Results: We successfully delivered all EO glue fiducials into the porcine bladders as discrete fiducials. They were well seen on CT, CBCT, and KV imaging. The glue fiducials had lower CT number values, but less CT number spread of the voxel percentile ranges consistent with the diminished contrast and less artifact than gold. The glue fiducial types had similar CT number characteristics. Conclusion: This study has shown that EO glue fiducials can be delivered with online visualization qualities comparable to gold fiducials without metal-related artifacts.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:1次