期刊论文详细信息
Materials & Design
Vascular embolization of radiopaque hydrogel microfiber using ultra-minimally invasive technique for stage-adjustable renal failure model
Yuya Hiroka1  Hirotaka J. Okano2  Yuta Kurashina3  Teppei Komatsu4  Hiroaki Onoe5  Hiroki Ohta6  Naoki Takakura7 
[1] Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8503, Japan;Division of Advanced Mechanical Systems Engineering, Institute of Engineering, Tokyo University of Agriculture and Technology, Koganei-shi, Tokyo 184-0012, Japan;Department of Mechanical Engineering, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan;Department of Neurology, the Jikei University School of Medicine, 3-25-8 Nishi-Shimbashi, Minato-ku, Tokyo 105-8461, Japan;Department of Radiological Sciences, Faculty of Health Sciences, Tokyo Metropolitan University, 7-2-10 Higashio-ku, Arakawa 116-8551, Japan;Division of Regenerative Medicine, Research Center for Medical Sciences, the Jikei University School of Medicine, 3-25-8 Nishi-Shimbashi, Minato-ku, Tokyo, 105-8461, Japan;School of Integrated Design Engineering, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama, 223-8522, Japan;
关键词: X-ray;    Microfiber;    Barium alginate hydrogel;    Catheter;    Radiopaque embolization;   
DOI  :  
来源: DOAJ
【 摘 要 】

Animal pathology models play an important role in elucidating pathology, evaluating drug efficacy, and studying therapeutic. This paper presents the creation of rats’ renal failure model by embolizing the renal artery using radiopaque hydrogel microfibers. By using a dual coaxial laminar flow microfluidic device, barium alginate gel microfibers containing zirconia particles were fabricated. Since the zirconia particles are radiopaque, the microfiber can be delivered and embolized while confirming the position of the microfiber in real-time under X-ray imaging. The delivery of microfibers through a catheter into the renal artery of rats to create a renal failure model was tested. The radiopaque microfibers were visualized by X-ray imaging when delivered by a catheter. Furthermore, the microfibers remained stable for 2 weeks after delivery. In addition, by adjusting the number of microfibers, two different rat models with severe and mild renal failure conditions were created. The proposed delivery of radiopaque hydrogel microfibers to create an embolization model is expected to be an effective approach to control the degree of symptoms and elucidate the pathology.

【 授权许可】

Unknown   

  文献评价指标  