期刊论文详细信息
Proceedings
Tomographic Measurement of Ammonia Distribution on a Hot Gas Test Bench
Bernhard Brandstätter1  Bernhard Fischbacher1  Bernhard Lechner1 
[1] Kompetenzzentrum—Das Virtuelle Fahrzeug Forschungsgesellschaft, 8010 Graz, Austria;
关键词: ammonia;    DUV;    SCR;    spectroscopy;    tomography;   
DOI  :  10.3390/proceedings2130876
来源: DOAJ
【 摘 要 】

In situ optical measurement systems for gas detection with high temporal resolution enable new possibilities of detection opportunities for continuous pipe gas streams. A tomographic absorption-based measurement system has been developed to detect the ammonia (NH3) concentration distribution within an exhaust pipe on a hot gas test bench. Multiple ammonia line concentrations are measured in situ by applying nondispersive absorption spectroscopy in the deep ultraviolet (DUV) region. The detectors consist of photodiodes in combination with optimized transimpedance amplifiers (TIV) allowing high sampling rates up to 3 kHz while providing a high signal-to-noise ratio (SNR). Despite the short path length of only eight centimeters a detection limit of 1 ppm has been achieved.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次