In situ optical measurement systems for gas detection with high temporal resolution enable new possibilities of detection opportunities for continuous pipe gas streams. A tomographic absorption-based measurement system has been developed to detect the ammonia (NH3) concentration distribution within an exhaust pipe on a hot gas test bench. Multiple ammonia line concentrations are measured in situ by applying nondispersive absorption spectroscopy in the deep ultraviolet (DUV) region. The detectors consist of photodiodes in combination with optimized transimpedance amplifiers (TIV) allowing high sampling rates up to 3 kHz while providing a high signal-to-noise ratio (SNR). Despite the short path length of only eight centimeters a detection limit of 1 ppm has been achieved.