期刊论文详细信息
Microbiology Spectrum
Detection of SARS-CoV-2 Infection in Gargle, Spit, and Sputum Specimens
Kirsi Liitsola1  Lotta Hagberg1  Carita Savolainen-Kopra1  Niina Ikonen1  Henna Mäkelä2  Thuan Vo2  Otto Helve2  Timothée Dub2  Eero Poukka2  Hanna Nohynek2 
[1] Expert Microbiology Unit, Department of Health Security, Finnish Institute for Health and Welfare, Helsinki, Finland;Infectious Disease Control and Vaccinations Unit, Department of Health Security, Finnish Institute for Health and Welfare, Helsinki, Finland;
关键词: alternative testing methods;    COVID-19;    gargle;    nasopharyngeal swab;    SARS-CoV-2;    spit;   
DOI  :  10.1128/Spectrum.00035-21
来源: DOAJ
【 摘 要 】

ABSTRACT The gold standard for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection diagnosis is reverse transcription (RT)-PCR from a nasopharyngeal swab specimen (NPS). Its collection involves close contact between patients and health care workers, requiring a significant amount of workforce and putting them at risk of infection. We evaluated self-collection of alternative specimens and compared their sensitivity and cycle threshold (CT) values to those of NPS. We visited acute coronavirus disease 2019 (COVID-19) outpatients to collect concomitant NPS and gargle specimens and had patients self-collect gargle and either sputum or spit specimens the next morning. We included 40 patients and collected 40 concomitant NPS and gargle specimens, as well as 40 gargle, 22 spit, and 16 sputum specimens the next day (2 patients could not produce sputum). All specimens were as sensitive as NPS. Gargle specimens had a sensitivity of 0.97 (95% confidence interval [CI], 0.92 to 1.00), whether collected concomitantly with NPS or the next morning. Next-morning spit and sputum specimens showed sensitivities of 1.00 (95% CI, 1.00 to 1.00) and 0.94 (95% CI, 0.87 to 1.00]), respectively. The gargle specimens had significantly higher mean CT values of 29.89 (standard deviation [SD], 4.63; P < 0.001) and 29.25 (SD, 3.99; P < 0.001) when collected concomitantly and the next morning, respectively, compared to NPS (22.07 [SD, 4.63]). CT values obtained with spit (23.51 [SD, 4.57]; P = 0.11) and sputum (25.82 [SD, 9.21]; P = 0.28) specimens were close to those of NPS. All alternative specimen collection methods were as sensitive as NPS, but spit collection appeared more promising, with a low CT value and ease of collection. Our findings warrant further investigation. IMPORTANCE Control of the COVID-19 pandemic relies heavily on a test-trace-isolate strategy. The most commonly used specimen for diagnosis of SARS-CoV-2 infection is a nasopharyngeal swab. However, this method is quite uncomfortable for the patient, requires specific equipment (nose swabs and containers), and requires close proximity to health care workers, putting them at risk of infection. Developing alternative sampling strategies could decrease the burden for health care workers, help overcome potential shortages of equipment, and improve acceptability of testing by reducing patient discomfort.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次