BMC Oral Health | |
Presence of voids after three obturation techniques in band‐shaped isthmuses: a micro‐computed tomography study | |
Pengfei Zhang1  Fen Zhao1  Keyong Yuan1  Qiaoqiao Jin1  Zhengwei Huang1  | |
[1] Department of Endodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University; | |
关键词: Isthmus; micro-CT; Obturation techniques; Voids; | |
DOI : 10.1186/s12903-021-01584-2 | |
来源: DOAJ |
【 摘 要 】
Abstract Background The objective of the present micro-computed tomography (micro-CT) study was to assess the presence of voids in band-shaped isthmuses obturated using three different filling techniques. Methods Twenty-four artificial molar teeth with a band-shaped isthmus were allocated to three groups (n = 8) for obturation, according to the filling technique: single-cone (SC), continuous wave of condensation (CWC) or lateral condensation (LC). Obturation was performed with gutta-percha (GP) cones and iRoot SP (Innovative Bioceramix, Vancouver, Canada). Post-filling micro-CT scanning was performed. The percentage of filling materials and void volumes were calculated in the isthmus areas and data were analyzed using one-way ANOVA and Tukey tests. Results The mean percentage of void volumes and corresponding filling percentages in the isthmus areas after obturation in the SC groups was 22.98 % ± 1.19 %, 77.02 % ± 1.19 %; in the CWC groups 10.46 % ± 2.28 %, 89.54 % ± 2.28 %; and in the LC groups was 13.14 % ± 1.85 %, 86.86 % ± 1.85 %, respectively. Conclusions In band-shaped isthmus area, the obturation quality of CWC was superior to SC and LC techniques.