Comparison of Different Types of Static Computer-Guided Implant Surgery in Varying Bone Inclinations
Dinesh Rokaya1  Sirichai Kiattavorncharoen2  Pisut Thangwarawut3  Pokpong Amornvit4 
[1] Department of Clinical Dentistry, Walailak University International College of Dentistry, Walailak University, Bangkok 10400, Thailand;Department of Oral and Maxillofacial Surgery, Mahidol University, Bangkok 10400, Thailand;Education Program in Implant Dentistry, Mahidol University, Bangkok 10400, Thailand;PPFACEDESIGN, The S Clinic, Bangkok 10120, Thailand;
关键词: dental implant;    accuracy;    computer-guided surgery;    bone inclination;    surgical guide;    stent;   
DOI  :  10.3390/ma15093004
来源: DOAJ
【 摘 要 】

This research aimed to compare the accuracy of dental implant placement among three types of surgical guide: metal sleeve with key handle (Nobel guide, Nobel Biocare, Göteborg, Sweden), metal sleeve without key handle, and non-sleeve without key handle (Dentium full guide kit, Dentium Co., Seoul, Korea) when placing the implant in different bone inclinations. A total of 72 polyurethane bone models were fabricated in different inclinations (0°, 45°, and 60°). The dental implants were placed in bone models following the company’s recommendations. After dental implants were installed, the digital scans were done by an extraoral scanner. The deviations of the dental implant position were evaluated by superimposition between post-implant placement and reference model by using GOM inspect software. The deviation measurement was shown in 5 parameters: angular deviation, 3D deviation at the crest, 3D deviation at the apex, lateral linear deviation, and vertical linear deviation. The data were analyzed using One-way ANOVA and post-hoc tests at a significance level of 0.05. The accuracy of the dental implant position was not significantly influenced by the difference in the surgical guide system (p > 0.05). There were significant differences between placed and planned implant positions in the different inclinations of the bone. A significant difference was found in all parameters of 0° and 60° bone inclinations (p < 0.05). At 0° and 45°, angulated bone showed significant differences except in 3D deviation at the apex. Between 45° and 60° were significant differences only in angular deviation. Within the limitations of this study, the accuracy of implant placement among three types of surgical guides (Non-sleeve without key handle, Metal sleeve without key handle, and Metal sleeve with key handle) from two companies (Dentium and Nobel Biocare) was similar. Hence, the operators can choose the surgical guide system according to their preference. The inclination of bone can influence the angulation of dental implants.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次