Monitoring cold water injections for reservoir characterization using a permanent fiber optic installation in a geothermal production well in the Southern German Molasse Basin
Sven Haberer1  Daniela Pfrang2  Felix Schölderle2  Florian Einsiedl2  Kai Zosseder2  Martin Lipus3  Thomas Reinsch4 
[1] Baker Hughes, Baker-Hughes-Straße 1, 29221, Celle, Germany;Chair of Hydrogeology, Technical University of Munich, Arcisstraße 21, 80333, Munich, Germany;Section Near-Surface Geophysics, GFZ German Research Centre for Geosciences, Telegrafenberg, 14473, Potsdam, Germany;Section Near-Surface Geophysics, GFZ German Research Centre for Geosciences, Telegrafenberg, 14473, Potsdam, Germany;Fraunhofer IEG, Fraunhofer Research Institution for Energy Infrastructures and Geothermal Systems IEG, Am Hochschulcampus 1, 44801, Bochum, Germany;
关键词: Geothermal;    Fiber optic monitoring;    DTS;    DAS;    Reservoir characterization;    Flow zone;    Bavarian Molasse Basin;   
DOI  :  10.1186/s40517-021-00204-0
来源: Springer
PDF
【 摘 要 】

Fiber optic sensing has gained importance for wellbore monitoring and reservoir characterization in geothermal fields as it allows continuous, spatially highly resolved measurements. Distributed acoustic sensing (DAS) and distributed temperature sensing (DTS) technologies, among others, enable monitoring of flow regimes and heat transport inside the wellbore to describe the dynamical behavior of the reservoir. The technically challenging installation of a permanent fiber optic monitoring system in a geothermal production well over the entire wellbore length was conducted for the first time at the geothermal site Schäftlarnstraße in Munich, Germany. One cable with two DAS fibers, two DTS fibers, and one fiber for a downhole fiber optic pressure/temperature gauge were clamped to ¾-in. sucker rods and installed to 3.7 km measured depth to collect data from the wellbore after drilling, during testing, and during operations. We present DTS profiles during 3 months of well shut-in and show the results of two cold water injection tests conducted to localize inflow zones in the reservoir and to test the performance of the fiber optic setup. A vertical displacement in temperature peaks of approximately 1.5 m was observed during the injection tests, presumably resulting from thermal contraction of the sucker rod–cable setup. This was verified by analyzing the strain information from the DAS records over 1 h of warm-back after cold water injection with the calculated theoretical thermal contraction of DTS of the same period. We further verified the flowmeter measurements with a gradient velocity analysis of DTS profiles during injection. Intake to the major inflow zone was estimated to 93.5% for the first injection test, respective 94.0% for the second, intake of flowmeter was calculated to 92.0% for the same zone. Those values are confirmed by analyzing DTS profiles during the warm-back period after the well was shut.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202110144301739ZK.pdf 6337KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:9次