Material properties of human vertebral trabecular bone under compression can be predicted based on quantitative computed tomography
Dominic Gehweiler1  Martin Schulze2  Oliver Riesenbeck3  Marius Schultz3  Michael J. Raschke3  Dirk Wähnert4 
[1] AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos, Switzerland;University Hospital Muenster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, Building W1, 48149, Muenster, Germany;Department of Orthopedics, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48149, Muenster, Germany;University Hospital Muenster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, Building W1, 48149, Muenster, Germany;University Hospital Muenster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, Building W1, 48149, Muenster, Germany;Department of Trauma Surgery and Orthopedics, Protestant Hospital of Bethel Foundation, University Hospital OWL of Bielefeld University, Campus Bielefeld-Bethel, Burgsteig 13, 33627, Bielefeld, Germany;
关键词: Biomechanics;    Human vertebra;    Cancellous bone;    Material properties;   
DOI  :  10.1186/s12891-021-04571-4
来源: Springer
PDF
【 摘 要 】

BackgroundThe prediction of the stability of bones is becoming increasingly important. Especially osteoporotic vertebral body fractures are a growing problem and an increasing burden on the health system. Therefore, the aim of this study was to provide the best possible description of the relationship between the material properties of human vertebral trabecular bone measured under the most physiological conditions possible and the bone mineral density (BMD) determined by clinical quantitative computed tomography (QCT).MethodsForty eight cylindric cancellous bone samples with a diameter of 7.2 mm obtained from 13 human fresh-frozen lumbar vertebrae from 5 donors (3 men, 2 women) have been used for this study. After the specimens were temporarily reinserted into the vertebral body, the QCT was performed. For mechanical testing, the samples were embedded in a load-free manner using polymethylmetacrylate (PMMA). The surrounding test chamber was filled with phosphate buffered saline (PBS) and heated to 37 °C during the test. After 10 preconditioning load cycles, destructive testing was performed under axial compression. After determining the fracture site, BMD has been evaluated in this region only. Regression analyses have been performed.ResultsFracture site had an average length of 2.4 (±1.4) mm and a position of 43.9 (±10.9) percent of the measurement length from the cranial end. No fracture reached the embedding. The average BMD at the fracture site was 80.2 (±28.7 | min. 14.5 | max. 137.8) mgCaHA/ml.In summary the results of the regression analyses showed for all three parameters a very good quality of fit by a power regression.ConclusionThe results of this study show that QCT-based bone density measurements have a good predictive power for the material properties of the vertebral cancellous bone measured under near to physiological conditions. The mechanical bone properties of vertebral cancellous bone could be modelled with high accuracy in the investigated bone density range.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202109174676030ZK.pdf 1147KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:9次